Differential Pressure switch  

Differential Pressure switch DS-205 D

The mechanical differential pressure switch/ differential pressure monitor DS-2 with 4-hole plastic base ring, is used for monitoring above-atmospheric, differential and below-atmospheric pressure of clean air, gaseous, non-aggressive media in air ducts, air intake or exhaust devices. As a flow monitor, differential pressure governor, pressure controller for flow monitoring at electric heating registers as well as for monitoring V-belts and filters, as air pressure deficiency protection for monitoring ventilators, dampers, or as a limit value controller. Switch point adjustment is done internally using the internal precision scale. These instruments are factory-calibrated.

The DS-2 differential pressure sensor is extra with ASD-06 connection set (2 m connection hose, two pressure connection nipples, screws).

Technical data
Max. pressure
5000 Pa (50 mbar)
Pressure range
high adjustment accuracy due to individual laser-etched scale for each switch
Pressure range (adjustable)
100…1000 Pa (1.0...10.0 mbar)
Switching capacity (Contact load)
5 (0.8) A, 250 V AC
4 (0.7) A, 30 V DC
Contact
single-pole potential-free changeover contact, multi-layer contact, gold-plated (DDC compatible)
Media temperature
–30 ...+85 °C
Operating Difference approx.
0.4 mbar ± 15 %/div>
Pressure connection
P1 (+) for higher pressure
P2 (–) for lower pressure Ø 6.2 mm (nipples)
Electrical connection
0.14 - 1.5 mm2, via terminal screws on circuit board
Housing
base: material PC (10 % GF), colour light grey (similar to RAL 7035),Snap-On lid: material PC, transparent, cable gland PG 11 with strain relief
Membrane
silicone, LSR (Liquid Silicon Rubber, tempered at +200 °C, non-outgassing, LABS-free, no emission of varnish-adhesion inhibiting substances), long-term stability of switching points due to trapezoidal bead membranes
Humidity
⟨ 90 % r. H., non-precipitating air
Mounting
by 4-hole base ring , plastic(included in the scope of delivery), recommended mounting position:vertical (pressure connections downward) – factory setting, horizontal (cap up/ down)
Protection class
II (according to EN 60 730)
Protection type
IP 54 with top cover (according to EN 60529)
Standards
CE conformity, low-voltage directive 2014/ 35/ EU
Tests
DVGW (according to DIN 1854), VDE 0630, EN 61058, directive on gas devices 2009/ 142/ EU, CE 0085 A P 0918
Function
Contact 1 - 2 breaks when pressure/ differential pressure rises to the present value. Contact 1 - 3 closes when pressure/ differential pressure drops and can be used as signal contact.